Search found 7 matches

by dirtytorque
Tue Jul 27, 2010 11:39 am
Forum: Datalog Viewing, Graphing and Analysis
Topic: small issue with Linux version field select
Replies: 3
Views: 704

small issue with Linux version field select

hi.
I am using verison 2.959 on Linux.
My issue is that not all of the field selct options appear.I can't scroll down and so can't access my EGT logs on my linux box.
yes i can use windows to access all these out of reach fields but it would be nic to be able to do it in linux too.
Just bringing it ...
by dirtytorque
Thu May 21, 2009 12:10 pm
Forum: Wiring and Sensors
Topic: voltage drop and electrical issues
Replies: 4
Views: 539

Re: voltage drop and electrical issues

what voltage do you get at the input of the main voltage regulator on the MS board?
Do you see battery terminal voltage?
by dirtytorque
Thu Nov 20, 2008 9:59 am
Forum: Injectors, Fuel & Air Supply
Topic: my PWM idle valve hums
Replies: 5
Views: 645

Re: my PWM idle valve hums

pwm valves hum.
by dirtytorque
Sun Aug 31, 2008 11:00 am
Forum: MS-II Ignition Setup, Tuning, and Troubleshooting
Topic: Idea for ignition tuning for best torque
Replies: 21
Views: 2797

Re: Idea for ignition tuning for best torque

Problem is though by the time you have heard the det and then pressed the button the engine may have moved on to another point and so you end up retarding the wrong point robbing you of power unecessarily?!?
I have just ordered a TPIC8101 microchip so I can get MS to log knock and retard the timing ...
by dirtytorque
Wed Mar 05, 2008 12:32 pm
Forum: Tuning Fuel and Air
Topic: Injections per Engine Cycle
Replies: 3
Views: 665

bump.

:)
by dirtytorque
Sun Mar 02, 2008 4:07 pm
Forum: Tuning Fuel and Air
Topic: Injections per Engine Cycle
Replies: 3
Views: 665

Injections per Engine Cycle

:RTFM:

MS-11 Board version 3
code 2.88

Hello



Injections per Engine Cycle (aka. "squirts") is set the number of squirts you want per engine cycle. You want this to be set so that your idle pulse width is no less than 2.0 ms, if possible, and your Req_Fuel is less than 15-18 milliseconds, but ...