If your question is about troubleshooting, configuration, or tuning, you MUST include your processor type (MS-I or MS-II) and code version in your post. If your question is about PCB assembly or modifications, you must also include the main board version number (1.01, 2.2 or 3.0). For tuning/troubleshooting questions, please attached a datalog and your MSQ file to your post.
If you have questions about MS1/Extra or MS2/Extra code configuration or tuning, please post them at www.msextra.com Such questions posted here will be moved to: a temporary MSextra sub-forum, where they will be removed after 7 days
The full forum rules are here: Forum Rules, be sure to read them all regularly.
Stumbling when rad fan comes on
I let it sit about 20 minutes (until the traffic backup somewhat cleared up), and started again - it was still running a little lean (16-17 range), but not dangerously so. The MS-II is in the glove box, and I opened it and the MS case was quite warm (to the point that I probably couldn't hold my hand on it for 20 seconds). Once I got back to highway speeds, then the problem seemed to go away. As I got back near home and back into some more stop-go traffic, it started to mildly act up again.
Unfortunately, I didn't have my laptop with me, so I didn't get a chance to datalog it.
Today, I wanted to verify that the rad fan was coming on, so I checked and it was. To be clear/sure when I'm driving that it's turned on, I wired a small light on the dash to the s1 (along with the wire going to the relay for the fan), so I could see visually when the fan kicked on. In testing the light, I used the spare port settings screen to adjust the variable to force the fan on (so I could verify that the dash light was working etc.), and once it did the engine started acting very much like it did before. This is when the engine is cold. So, I'm deducing that the problem wasn't necessarily because the engine was warm, but rather because it was triggering the fan to turn on. I was starting to think heat soak problems etc., but it doesn't seem that way.
So, I datalogged it this time. I've attached the datalog and msq. The datalog is very short - just starting the engine, turning on the fan (where I have to give it a little throttle just to keep running), then it settles down a little, then I turn the fan off, then stop the logging. It's very obvious when the fan is turned on - the graphs spike all over the place, for example, the coolant temp reading drops dramatically, which seems to cause it to feed more fuel, then it's like a roller coaster with smaller and smaller lumps on the graph. I have a volt meter in the truck, and I didn't see any sudden wavering of the voltage when the fan kicked on.
I have S1 going to a 30 AMP relay, the load of the relay goes right from the battery (via a fuse) to the relay and from the relay to the fan.
Any ideas, or things that I should check, or anything obvious?
Thanks in advance.
Re: Stumbling when rad fan comes on
I've attached 2 datalogs:
1. In the 'first datalog', I have the engine running and then using the spare ports screen, I manually enable the spare port (about 928sec) that goes to the relay for the fan. You can see the rpm drop etc. I then unplugged the power source to the relay (so the spare port would still trigger the relay, but no power going through the load part of the relay to the fan.) This did not seem to have the same effect. You'll see the TP spike - the throttle was never physically depressed like this, although I did give it a little throttle to keep it from stalling.
2. At some point, when I had the power to the fan relay disconnected, I noticed the light on the dash that I wired to the spare port (s1 on the relay board) was flashing on and off - on for <1 sec, off for about 1 sec, then on again, but not in a totally consistent pattern. So, I put power back to the fan, started the truck and then datalogged the result. This is a lot more like what I had experienced on the longer trip before. At about 1348sec I disabled the spare port, and it settles a little. I have the hysteresis set to 5 - it almost seems like it's set to .5 - the way it cycles on and off like it does. You can see the TP wavering all over the place - the throttle pedal was physically in the same spot until about the 1348sec position.
Thanks.
Re: Stumbling when rad fan comes on
-
Matt Cramer
- Super Squirter
- Posts: 2951
- Joined: Sat Jul 03, 2004 11:35 am
Re: Stumbling when rad fan comes on
http://www.bgsoflex.com/megameet2008/me ... gnding.pdf
Re: Stumbling when rad fan comes on
I re-traced all my grounds and found that I had the fan ground on the same lug as all the sensor grounds. So, I moved the fan ground over to the other side of the engine bay, and so far the problem seems to have been resolved. It isn't warm enough out tonight to get it very hot driving around, but I was able to let it idle in the garage long enough for the fan to kick in, and no drop in rpm, no fluctuating etc. So, I think it's resolved.
Do you sell, or know where I can get, a good terminal block/ground block? Right now, I have a heavy gauge wire going from a lug on the sheet metal (a very heavy gauge wire direct from the - on the battery shares this lug, so it should be a good straight path to ground), and this wire is about 8" long and terminates with a ring connector on a bolt with all the sensor grounds and the MS-II ground also all with ring connectors on this same bolt. All the terminal blocks I've found aren't a common connection, they're more like the one in this link: http://order.waytekwire.com/productdeta ... L%20BLOCK/ . I figured that a good grounding/terminal block would be a better (and neater/tidier looking) place for all the grounds than the bolt that I currently have. Your thoughts?
Re: Stumbling when rad fan comes on
Rover V-8
MSII V3
EDIS